POWER
ACCESSORIES |
SPM200 |
NEWMAR SITE POWER MONITOR
Web-enable and integrate
intelligence to any site’s AC and DC power system for 24/7
monitoring, alarm condition notification, and data logging of
vital electrical functions. All programmable, accessible, and
managed via the Internet: TCIP or SNMP. View current conditions
and log 30 day history of DC and AC power status at remote sites
before dispatching personnel.
The Site Power Monitor is
designed specifically for monitoring power supplies, rectifiers,
batteries, converters, inverters, UPS, distribution panels, and
AC power at communication sites, base stations, outdoor
enclosures, and command vehicles via Ethernet or Wireless
connection. The palm sized unit can be rack, DIN-rail, or wall
mounted and is easily adapted to virtually any make of power
system via nine sensor input ports which capture and stream
critical data via the internet for analysis and logging of site
history. Web page based programs are easily user configured for
site parameters with up to 50 desired alarm conditions settings
and multiple automatic notification options by e-mail, PDA, and
mobile phone.
Sites without internet access
can use the monitor solely as a data logging instrument that
captures and retains a 30 day history file, ready for download
to a lap top computer during maintenance visits for recording
site history and analysis of component performance and failure
conditions. |
_small.jpg) |
PFM400 |
NEWMAR POWER FUNCTION MANAGER
The Power Function Manager
(PFM-400) is a system integrating component which converts
ordinary power supplies (Power Modules) into a fully integrated
and multifunctional power system. The unit provides for control,
monitoring, paralleling and protection of 12, 24 or 48VDC,
positive negative or floating ground power sources.
The PFM has a heavy duty (400 amp)
parallel tie point bus, digital output voltage and amperage
monitoring, system and battery status lights, load distribution
circuits, low voltage battery disconnect (ideal for systems with
battery back-up) and summary alarm contacts, all combined in a
compact, rack-mount housing which serves as a master DC power
management and distribution center. A high amp rack-mount
ground/return bus is provided.
The PFM may be used for integration, control, monitoring and
protection of numerous different types of power sources, such as
AC-DC rectifiers, regulated power supplies or DC-DC converters.
Note: Installation of O-ring diodes recommended for paralleling
of most power sources. O-ring diode output is standard on PM
Series Power Modules. |
 |
|
Battery
Disconnect Panels
(Power Plant
Accessories) |
BATTERY DISCONNECT PANELS
12VDC,
24VDC
or 48VDC
- Provides over-current protection in high
current battery wiring applications
- Provides a convenient means of disconnecting
batteries from power plant during servicing
- High current single pole breaker is mounted
into dedicated black finish panel
- Auxiliary contacts standard (form C)
- Adapts for 19" or 23" racks.
- Voltage Rating: 12, 24 or 48VDC
- Model Circuit Breaker Available Position
Amperage
- BDP-1 1 50, 75, 100
- BDP-2 2 50, 75, 100
- Special order 125 to 400 amp panels available
- contact GFS Power
|
 |
|
Battery
Trays
(Power Plant Accessories) |
BATTERY TRAYS
- Heavy gauge cold rolled steel trays to fit
standard 19" racks with 17 3/4" inner dimensions.
- Ideal for holding up to four 100 amp-hour
front terminal batteries.
- Inner dimensions: 17.25" Wide x 19.04" Deep.
- 350 lb. capacity.
- Black powder coat finish.
- Mounting hardware supplied.
- Weight 12 lbs.
- 23" trays also available in various depths.
|
 |
|
Return
Bus Bar
(Power Plant Accessories) |
BUS BARS
- 800 amp rated nickel-plated copper bus bar for
use as heavy duty DC positive or negative connection point in rack
installations
- Mounts to rear of rack; adaptable to 19" or
23" rack widths
- All mounting hardware including isolated
stand-offs provided
- Multiple attachment holes in two sizes
provided for single and dual hole lugs:
- 18 ea. @ .312" x .500"
- 6 ea. @ .437" round
- 4 ea. @ .281" round
- Bar is 2" high x 1/4" thick x 19 1/2" wide, 4
lbs.
- Projection depth from rear of rack: 7 1/2
inches
|
 |
|
DC
Quick Connect Wiring Kits
(Power Plant
Accessories)
|
DC QUICK CONNECT WIRING KITS
- Allow for quick installation and removal of
rectifiers
- Designed specifically for use with NEWMAR 1KW
PM Series Power Modules and Power Function Manager (see pages 6-7)
in stacked rack configuration.
- Wiring harness is fitted with "Anderson"
quick-connect and ring lug terminals; all wires tie- wrapped into
proper position for quick and easy installation.
- Simplifies parallel wiring of up to 6 modules
- Facilitates "hot" change-out of modules
without system shutdown
- Wire gauge 6 AWG
MODELS:
- QCK-3 for 2-3 Power Modules plus PFM and
return bus bar; 3 lbs.
- QCK-6 for up to 6 Power Modules plus PFM and
return bus bar; 4 lbs.
|
 |
|
Rear
Rack Covers
(Power Plant Accessories) |
REAR RACK COVERS
- Clear plastic panels attach to rear of racks
to protect service personnel by preventing accidental contact with
"live" terminals, etc., from top, sides and rear.
- Holes in rear panels allow for flow-through
ventilation of fan-cooled components
- Model indicates height of cover in rack units
and rack width in inches:
- RRC-3-19 3 RU, 19" rack
- RRC-7-19 7 RU, 19" rack
- RRC-3-23 3 RU, 23" rack
- RRC-7-23 7 RU, 23" rack
- May be installed at 14" or 17" rear depth
- Multiple covers may be stacked to accommodate
system height
- All mounting hardware included
- Weight: 2 lbs.
- Special 2RU rear cover also available for DST
panels - see Circuit Breaker DC Distribution Panels
|
 |
|
PM
Power Module |
CHARGER FUNCTION
BOARD for
PM POWER MODULES (converts standard PM rectifier module into three stage
battery charger with gel/lead-acid selector)
- Available for
12VDC,
24VDC and 48VDC
models
|
 |
|
PX Series
(Electrical Installation Accessories) |
THRU-DEX WATERPROOF
JUNCTION BOXES and FEED-THROUGH FITTINGS
PX SERIES
- Waterproof junction box with terminal strip
for electronic connections in areas subject to spray, washdowns,
etc.
- Rugged, non-corrosive polypropylene housing
- "Universal" cut-to-fit cable entries, diameter
range: .14 -.81"
- Brass compression screw terminals
- Wire gauge: 16 AWG
Model
Terminals
- PX-1
6 pair
- PX-2
12 pair
- PX-3
18 pair
|

|
BX
Series (Electrical
Installation Accessories) |
THRU-DEX WATERPROOF
JUNCTION BOXES and FEED-THROUGH FITTINGS
BX SERIES
Splash proof junction box with terminal strip
- Rugged cast aluminum box and cover with enamel
finish
- Multiple rubber grommet cable
- entries
- Brass compression screw terminals
Model Terminals
Wire Gauge
- BX-1
6 pair
16 AWG
- BX-2
12 pair
16 AWG
- BX-3
22 pair
14 AWG
|

|
CCX
Series(Electrical Installation Accessories) |
THRU-DEX WATERPROOF
JUNCTION BOXES and FEED-THROUGH FITTINGS
CCX SERIES
- Create a 100%waterproof seal when routing
cables through communication huts, cabinets, etc.
- Allow installation/removal with connector
still attached
- Rugged weatherproof nylon with neoprene seal
- Entry hole predrilled
Model Cable Dia. Range
Max Conn. Dia.
- CCX-R
.47"-.59"
1.57"
- CCX-S
.35"-.55"
.83"
- CCX-T
.18"-.35"
.83
|

|
DX
Series
(Electrical Installation Accessories) |
THRU-DEX WATERPROOF
JUNCTION BOXES and FEED-THROUGH FITTINGS
DX SERIES
- Similar to CCX Series except installer drills
holes in seal to accommodate cable(s)
- Multiple cables may be routed through a single
fitting
Connector Model
Drill-Thru Aperture
Max
Diameter
- DX-2
1.2"
1.2"
- DX-3
1.65"
1.65"
- DX-5*
2.0"
2.0"
*Aluminum Housing |

|
|
Low
Voltage Disconnect
(Installation Accessories) |
LOW VOLTAGE DISCONNECTS (LVD)
Discharging batteries beyond a critical low voltage
can damage the batteries and/or load, and require a longer recharge
interval. A low voltage disconnect prevents this condition.
MODELS:
- LVD 12-30, LVD 12-75
(Neg. Ground)
- LVD 24-20, LVD 24-50
(Neg. Ground)
- LVD 48-30 (Pos. Ground)
|
 |
Emergency
Relay/Charger ERC
(Installation Accessories) |
EMERGENCY RELAY/CHARGER - ERC The E.R.C. allows emergency battery tie-in to a radio
system that is normally operated by a power supply.
Under
normal conditions the radio is connected through the ERC to the power
supply and the back-up battery receives only a trickle charge to keep it
in peak condition.
In the event of AC power failure a relay automatically connects
the radio to the back-up battery, restoring the system within one
second. When AC power is restored the radio is automatically reconnected
to the power supply and the trickle charge resumes to the battery.
|
 |
Antenna/Coax
Switches
(Installation Accessories) |
ANTENNA/COAX SWITCHES
Two position switch allows manual selection of one of two antennas with
a single radio or one of 2 radios with a single antenna. Die cast aluminum case
Operates on 12VDC, single pole, double throw.
Permits remote selection of two antennas with a single radio.
|


|
Microphone
Clips
(Installation Accessories)
|
MICROPHONE CLIPS All stainless steel. For securing
standard VHF microphone when not in use. Lift to release.
|

|
|
Temperature Compensation Sensors |
TEMPERATURE
COMPENSATION SENSORS
The TCS is an optional remote sensor for optimizing
the voltage output of your Phase Three charger based on ambient or
battery temperature.
It is designed for use only with the following
models: PT-14, PT-20, PT-25, PT-40, PT-70, PT-24-8, PT-24-13, PT-24-20,
PT-24-35, PT-24-40, as well as all Phase Three Modular Series models.
|
 |
|
Fuses |
GMT FUSES
AMPERAGES: 1, 3, 5, 10 and 15Amp |
 |
|
Plug-in
Circuit
Breakers |
PLUG-IN
MID TRIP CIRCUIT BREAKERS
AMPERAGES: 5, 10, 15, 20, 30, 40, 50, 75 and 100Amp |
 |
|
Rear
Terminal Cover Assembly Drawings |
DST SERIES - REAR TERMINAL COVER
ASSEMBLY Designed to protect service
personnel by preventing accidental contact with "live" terminals.
Covers rear, top and sides of bus bars in DC Distribution
Panels. |
 |