Newmar’s Isolated Series converters that provide input/output isolation, allowing use of negative ground electronics on off-highway vehicles which are usually employ positive ground battery systems. The ISP DC-DC Converters provide input/output isolation along with protection against line transients and voltage spikes.

Isolated Series
As well as voltage conversion, this series provides input/output isolation, allowing use of negative ground electronics on off-highway vehicles which typically employ positive ground battery systems. May also be used as a Voltage Stabilizer for sensitive equipment.
 

ISP Series
offer the benefits of an isolated converter (above) plus protection against line transients and voltage spikes typically caused by large DC motors and switching transients often encountered on fork lifts, locomotives and light rail. A special circuit clamps input spikes to a safe level, protecting both the converter and the powered equipment.

This product series is further enhanced with extra rugged construction of case and internal components for severe vibration applications.

Features: Isolated & ISP Series
• Reverse polarity protection
• Input fuse
• Output fuse
• Current limiting, short circuit proof output
• Automatic resetting thermal shutdown
• Input transient protection*
• High/low input voltage shutdown
• Polyurethane conformal coating on PC board
• Power “ON” light
• On/Off switch
  *ISP Series only

Performance Specifications: Isolated and ISP Series

Download Data Sheet - DC-DC Converters - Isolated and ISP Series


Output: 13.6 VDC (internally adjustable 12.6-14.5) or 24.5 VDC (or specify)
Ripple: 150 mV P-P Regulation: +/- 2% Line/Load Duty Cycle Ratings*: Intermittent - 20 minutes, max on time,20% duty, Continuous - 24 hours, 100% duty *Current limit set at approximately 105% of intermittent rating
Idle Current: (including power "on" indicator light) approx. 50 mA
Operating Temp:
    Isolated Series: 0-50° C; derate linearly from 100% @ 40° C to 50% @ 50° C
    ISP Series: see temperature rating curves (below)
Switching Frequency: 70Khz
Efficiency: 85% - typical.
DC Isolation:
Input/Output, Input/Chassis, Output/Chassis):
    Isolated Series: 250 VDC
    ISP Series: 1,400 VDC

Isolated Series
Model
Input
Voltage
Output
Voltage
Output Amps
Case
Size
Weight
Intermittent
Continuous
Lbs
Kg
12-12-12I
10-16**
13.6
12
8
C-8
6
2.7
12-24-6I
10-16**
24.5
6
4
C-8
6
2.7
12-12-35I
10-16**
13.6
35
20
C-9
12
5.5
12-24-18I
10-16**
24.5
18
10
C-9
12
5.5
48-12-6I
20-56
13.6
6
6
C-7
7
2.7
48-24-3I
20-56
24.5
3
3
C-7
7
2.7
48-12-12I
20-56
13.6
12
8
C-8
6
2.7
48-24-6I
20-56
24.5
6
4
C-8
6
2.7
48-12-18I
20-56
13.6
18
10
C-8
8
3.6
48-24-9I
20-56
24.5
9
5
C-8
8
3.6
48-12-35I
20-56
13.6
35
20
C-9
12
5.5
48-24-18I
20-56
24.5
18
10
C-9
12
5.5
**11.5 VDC minimum start-up voltage, then operates @ 10-16 VDC from 1 amp minimum to full load

ISP Series
Model
Input
voltage
Output
voltage
Output Amps
Case
Size
Weight
Intermittent
Continuous
Lbs
Kg
36-12-6ISP†
18-65
13.6
6
6
C-7
5
2.3
36-24-3ISP
18-65
24.5
3
3
C-7
5
2.3
36-12-18ISP
20-65
13.6
18
10
C-6
8
3.6
36-24-9ISP
20-65
24.5
9
5
C-6
8
3.6
36-12-35ISP*
20-65
13.6
35
20
C-9
12
5.5
72-12-6ISP
42-90
13.6
6
6
C-7
5
2.3
72-24-3ISP
42-90
24.5
3
3
C-7
5
2.3
72-12-18ISP
42-90
13.6
18
10
C-6
8
3.6
72-24-9ISP
42-90
24.5
9
5
C-6
8
3.6
110-12-18ISP
80-140
13.6
18
10
C-6
8
3.6
110-24-9ISP
80-140
24.5
9
5
C-6
8
3.6
† This model EMC and safety CE certified for sales within the European Union.
*Build to order only – 10 unit minimum

ISP Surge Protection
Transient Energy Capability:
36 VDC Input: 140 joules (Watt-Seconds) Peak Current, 2,000 Amps
72 & 110 VDC Input: 100 Joules (Watt-Seconds) Peak Current, 12,000 Amps

Temperature Specifications - ISP Series
Operating Temperature -40° C to +80°C Thermal shutdown @ 85° C Case Temperature

ISP Series Temperature/Amperage Derating Curves



Options
• operation as a battery charger or parallel/ redundant operation (contact factory)
• Other “Special” output voltages available

Extreme vibration mounting kit



The Extreme Vibration Mounting Kit is available to protect NEWMAR power converters from the extreme stresses of shock and vibration when mounted on high–vibration vehicles.



The kit (pictured here) replaces the standard vibration kit provided with the unit and fits into the unit's mounting flange to act as a "super shock absorber" for electronics in high-vibe applications. It is available to fit all NEWMAR units from 2 to 70 lbs. Specify KIT–L for units which weigh 2–15 lbs. and Kit–H for units which weigh 16-70 lbs.

 

 

 

Home Back Contact Us Terms Search Contents

For pricing and availability please email : sales@gfspower.com.au

Should you have a requirement that cannot be met from the current Web site please email us @ sales@gfspower.com.au

Reseller inquiries are welcome, please email: raymond@gfspower.com.au

Last modified: 16-Aug-2011  

Webmaster: raymond@gfspower.com.au